Electric Electrician handles safety switch installation in Melbourne homes and rental properties: adding RCD protection to circuits that have none, replacing worn or faulty units, and tracking down the cause when a switch won't stop tripping. Every device is trip-tested on completion and the work is certified.
Electric Electrician handles safety switch installation in Melbourne homes and rental properties: adding RCD protection to circuits that have none, replacing worn or faulty units, and tracking down the cause when a switch won't stop tripping. Every device is trip-tested on completion and the work is certified.

In short
A licensed A-Grade electrician. We check which of your circuits are protected, fit RCDs or combined RCBO breakers where protection is missing or failing, and time-test every device before we leave. If a switch is tripping rather than missing, we find the fault first, because a new device will not cure a leak in the wiring or an appliance. The price is agreed in writing up front.
The service
A circuit breaker looks after the cable, cutting the supply when a circuit is overloaded or shorted. A safety switch looks after people. It watches for current escaping to earth, through a damaged lead, a wet fitting or someone's body, and disconnects the supply in a fraction of a second.
If your home was wired before safety switches became standard, some or all of its circuits may have no RCD protection at all. An RCBO combines a breaker and a safety switch in one module, so each circuit can carry its own protection and a single faulty appliance no longer shuts down the rest of the house.
A tripping safety switch is usually reacting to something real. The usual suspects are an appliance with a failing element, water getting into an outdoor outlet or light, or cable damaged by a screw, a rodent or old age. Our guide on Safety Switch Keeps Tripping? Here's Why shows you how to narrow it down at home.
When we attend, we first confirm the device trips at the right current and time. Then we measure the circuits and appliances behind it to locate the leakage. If the switch itself has failed, we replace it. If the fault sits elsewhere, we repair that through our electrical fault finding service and leave the protection in place.
Since 29 March 2023, Victoria's rental minimum standards have required every power outlet and lighting circuit in a rented home to be connected to both a switchboard-type circuit breaker and a switchboard-type safety switch. Rental providers must also arrange an electrical safety check of all installations, fixtures and fittings by a licensed or registered electrician every two years, keep the record, and tell new renters when the last check was done.
Where a board already uses circuit breakers, RCD protection can usually be added to the power and lighting circuits. Older fuse boards may leave no option but to replace the whole board. Landlords and property managers get our findings in writing, and if smoke alarms are due as well, they can be done on the same visit through our smoke alarm installation service.
If your switchboard already has circuit breakers and space to work with, safety switches can often be added without starting again. If it still runs ceramic fuses, or the board has no room left, a switchboard upgrade is the better route. We look at the board first and tell you which applies before quoting.
Every safety switch has a test button. Press it every three months or so and the power on that switch should cut straight away. If nothing happens, the device needs replacing. Never bypass a switch that trips, and never swap one for a different rating to make the tripping stop.
You get one price, in writing, before work starts. It covers the safety switches or RCBOs, fitting them, trip-time testing of every device, a check of the circuits they protect, and the Certificate of Electrical Safety for the finished work.